The MUVE B330 is a Continuous Biological Detector and Collector purpose-designed for unmanned aerial systems (UAS) to provide realtime continuous monitoring of biological threats while on the move. The B330 leverages the legacy design and performance of the IBAC product line in a SWaP-optimized configuration. The SkyRanger ® R70 and R80 SkyRaider ™ serves as the platforms for the initial deployment of the MUVE B330 payload. The payload is designed to be intuitive, easy to use, and require minimal maintenance. Sensor display is provided via the Mission Control Station (MCS) piloting interface. Alarming conditions and collector status will be displayed to the Pilot to not only alert them to a threat, but also provide positive confirmation that a sample is being collected. The MUVE B330 provides next level protection to combat forces by identifying biological threats remotely and down range.

  • Assess the scene from a safe distance
  • Continuous air sampling provides real-time feedback of conditions
  • Allows for informed decision making prior to approaching a hazardous scene
  • Locate source of threat and track progression as the scene unfolds
  • Cover difficult terrain from the air to assess threat
  • Make a quick assessment of the threat perimeter
  • Alarm will initiate upon detection of hazardous conditions
  • Automated sample collection upon alarm indication
  • Mission Control Station (MCS) application provides plug-and-play operation of the MUVE B330 payload
  • Visually display threats on the map within MCS using easy to understand pin drops
  • Analyze, log, and access complex data in an easy-to-understand visual overlay
TechnologyUV Laser Induced Fluorescence (LIF)
Sample IntroductionAirborne particles; triggered aerosol sample collector
Sample PhaseAerosol; flow rate 4.0 L/min (0.14 ft3/min)
ThreatsSpores, vegetative bacteria, viruses, and toxins; particle size: 0.7 – 10 microns
Sensitivity<100 particles/L of air
Sampling & AnalysisContinuous sampling when in operation
Sample CollectionIntegrated sample collection
Display & AlertsMission Control Station (MCS)
OutputsAlarm Status, Diagnostics Status, Collector Status
Data Storage16 GB internal storage
Input Voltage16-36 VDC
Cold Start Time<5 mins
Operating Temp-32 to 49 °C
Operating Humidity5% to 99%, non-condensing
Storage Temp-39 to 52 °C
CommunicationEthernet
Dimensions19.3 x 19.3 x 21.6 cm
Weight1.44 kg
EnclosureWindform® SP (Composite polyamide based, carbon filled)